Item
Description
Room thermostat (wired or
wireless)
In case of wireless room thermostat
, see:
▪
Installation manual of the wireless room
thermostat
▪
Addendum book for optional equipment
In case of wired room thermostat without
multi-zoning base unit
, see:
▪
Installation manual of the wired room
thermostat
▪
Addendum book for optional equipment
In case of wired room thermostat with
multi-zoning base unit
, see:
▪
Installation manual of the wired room
thermostat (digital or analogue) + multi-
zoning base unit
▪
Addendum book for optional equipment
▪
In this case:
-
You need to connect the wired room
thermostat (digital or analogue) to the
multi-zoning base unit
-
You need to connect the multi-zoning
base unit to the outdoor unit
-
For cooling/heating operation, you also
need to implement a relay (field supply,
see addendum book for optional
equipment)
Wires: 0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪
[2.9]
Control
▪
[2.A]
Thermostat type
For the additional zone:
▪
[3.A]
Thermostat type
▪
[3.9] (read-only)
Control