Power meter
Description
2
Measures
(a)
: Compressor module
Connection
: X5M/3+4
Power meter type
: Single- or three-phase power meter
according to the power supply of the outdoor unit.
(a)
In the software the power consumption data of both meters is added so you do NOT have
to set which meter covers which power consumption.
Exceptional cases.
You can also use a second power meter if:
-
The power range of one meter is insufficient.
-
The power meter cannot easily be installed in the electrical cabinet.
-
230 V and 400 V three-phase grids are combined (very uncommon), because of
technical limitations of power meters.