11
|
Configuration
Installer reference guide
191
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
(a)
Use the menu structure instead of the overview settings. Menu structure setting [9.2.1]
replaces the following 3 overview settings:
•
[E-05]: Can the system prepare domestic hot water?
•
[E-06]: Is a domestic hot water tank installed in the system?
•
[E-07]: What kind of domestic hot water tank is installed?
In case of EKHWP, we recommend to use the following settings:
#
Code
Item
EKHWP
[9.2.1]
[E‑07]
Tank type
5:
EKHWP/HYC
N/A
[4-05]
Thermistor type
0: Automatic
[5.8]
[6-0E]
Maximum tank
temperature
≤70°C
In case of EKHWS*D* / EKHWSU*D*, we recommend to use the following settings:
#
Code
Item
EKHWS*D* / EKHWSU*D*
[9.2.1]
[E‑07]
Tank type
0:
EKHWS/E
N/A
[4-05]
Thermistor type
0: Automatic
[5.8]
[6-0E]
Maximum tank
temperature
≤75°C
In case of a third-party tank, we recommend to use the following settings:
#
Code
Item
Third-party tank
[9.2.1]
[E‑07]
Tank type
0:
EKHWS/E
N/A
[4-05]
Thermistor type
0: Automatic
[5.8]
[6-0E]
Maximum tank
temperature
≤75°C