16
|
Technical data
Installer reference guide
227
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
16 Technical data
A
subset
of the latest technical data is available on the regional Daikin website (publicly accessible). The
full set
of
latest technical data is available on the Daikin Business Portal (authentication required).
16.1 Piping diagram: Indoor unit
3D121963
Y1E
R2T
(A7P)
R5T
(A7P)
R1T
(A1P)
R4T
(A1P)
R5T
(A1P)
R8T
(A1P)
R2T
(A1P)
R3T
(A7P)
R4T
(A7P)
R6T
(A7P)
R3T
(A1P)
A
B
D
C
M1C
M1P
M4P
B1L
Y1S
S1NPL
B1PR S1PH
B1PW
M3S
a2
a1
b1
c1
c2
b2
A
d
d
D
B
C
e
D
D
d
d
g
f
g
g
E
g
h
i
i
h
j
k
l
m
n
o
p
q
q
o
r
s
s
A
Brine side
B
Refrigerant side
C
Water side
D
Field installed
E
DHW tank
a1
Space heating water IN (Ø22 mm)
a2
Space heating water OUT (Ø22 mm)
b1
Domestic hot water: cold water IN (Ø22 mm)
b2
Domestic hot water: hot water OUT (Ø22 mm)
c1
Brine IN (Ø28 mm)
c2
Brine OUT (Ø28 mm)
d
Shut-off valve
e
Automatic air purge valve
f
Safety valve
g
Shut-off valve
h
Manual air purge valve
i
Drain valve
j
Backup heater
k
Recirculation connection (3/4" G female)
l
Check valve
m
Muffler
n
Refrigerant pressure relief valve
o
Service port (5/16" flare)
p
Heat sink
q
Filter
r
Rectifier