9
|
LAN adapter
Installer reference guide
105
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
Wiring diagram
X1A
X3A
X5M
X2A
SG0 L SG1 L
N
L
P/P1 N/P2
S0 GND
LAN
X4A
OFF
ON
1 2 3 4 5 6 7 8
LD1 LD2 LD3 LD4
SS1
A15P
1
1
S3S
S1S
S2S
Q1DI
N
L
Q1DI
S1S
11 12
Q1DI
N L
S1S
L N
1
Full smart grid functionality.
Router
PV with controllable wall socket.
PV with potential free contact.
Electric pulse meter.
5 V DC pulse detection
(supplied by PCB).
Installer SWB
Field supply
1
Several wiring possibilities
Option
Wiring depending on model
A15P
LAN adapter PCB
LD1~LD4
PCB LED
Q1DI
# Circuit breaker
SS1
DIP switch
S1S
# SG0 contact
S2S
# SG1 contact
S3S
* Electrical pulse meter input
X*A
Connector
X5M
Field wiring terminal for DC
* Optional
# Field supply