6
|
Unit installation
Installer reference guide
59
EGSAH/X06+10UDA9W
Daikin Altherma 3 GEO
4P598592-1A – 2019.12
1×
T25
9
Lift the uncoupled piping and use the handle on the front of the module to
carefully slide the module out of the unit. Make sure the module remains level
and does not tilt forward.
CAUTION
The hydro module is heavy. It requires at least two persons to carry it.
NOTICE
Make sure not to damage any insulation during the removal process.
Removal after first installation
If the water and brine circuits have been filled before, remaining water and brine
need to be drained from the hydro module before removal. In this case, perform
the following actions:
1
Remove the insulation from the shut-off valves. (See step 2 in
remove the hydro module from the unit"
2
Close the shut-off valves by turning the lever handles.
4×
3
Remove the lower hydro module cover. (See step 5 in
57].)