Main Functions
SiEN12-710A
26
Function and Control
1.2 Power-Airflow Dual Flaps, Wide-Angle Louvers and
Auto-Swing
Power-airflow
Dual Flaps
The large flaps send a large volume of air downwards to the floor. The flap provides an optimum
control area in cooling, heating and dry mode.
Heating Mode
During heating mode, the large flap enables direct warm air straight downwards. The flap
presses the warm air above the floor to reach the entire room.
Cooling Mode
During cooling mode, the flap retracts into the indoor unit. Then, cool air can be blown far and
pervaded all over the room.
Wide-Angle
Louvers
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees a
comfortable air distribution.
Auto-Swing
In case of FTKS25/35D, FTXS25/35E
The following table explains the auto swing process for heating, cooling, dry and fan :
COMFORT
AIRFLOW Mode
FTKS25/35D, FTXS25/35E
The vertical swing flap is controlled not to blow the air directly on the person in the room.
"
The airflow rate is controlled automatically within the following steps.
Cooling: L tap – MH tap (same as AUTOMATIC)
Heating: ML tap – M tap
"
The latest command has the priority between POWERFUL and COMFORT AIRFLOW.
Vertical Swing (up and down)
Horizontal Swing
(right and left: manual)
Cooling / Dry
Heating
Fan
(R4281)
10
°
50
°
(R4282)
30
°
65
°
(R4283)
5
°
70
°
(R4284)
45
°
45
°
Heating
Cooling
(R4303)
70
°
(R4302)
5
°
Summary of Contents for 2MKS40FV1B
Page 11: ...Introduction SiEN12 710A x ...
Page 12: ...SiEN12 710A List of Functions 1 Part 1 List of Functions 1 Cooling Only 2 2 Heat Pump 4 ...
Page 17: ...Heat Pump SiEN12 710A 6 List of Functions ...
Page 25: ...Heat Pump SiEN12 710A 14 Specifications ...
Page 111: ...Instruction SiEN12 710A 100 Operation Manual ...
Page 199: ...Wiring Diagrams SiEN12 710A 188 Appendix ...
Page 203: ...SiEN12 710A iv Index ...