SiEN12-710A
Outdoor Unit
Removal Procedure
175
1.7 Removal of the Compressor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove the terminal
cover.
"
Be careful so as not to burn
the compressor terminals or
the name plate.
Make a note.
2
Disconnect the flag-
shaped terminals.
3
Detach the terminals by
long nose pliers.
Undo the hooks by a
flat screwdriver to
remove the overheating
protector.
4
Detach the overload
protector.
(R7637)
Terminal cover
Red (U)
Yellow (V)
Blue (W)
(R7638)
Protection bushing
for lead wires
(R7639)
(R7640)
Summary of Contents for 2MKS40FV1B