![background image](http://html.mh-extra.com/html/daikin/2mks40fv1b/2mks40fv1b_service-manual_501074029.webp)
Printed Circuit Board Connector Wiring Diagram
SiEN12-710A
18
Printed Circuit Board Connector Wiring Diagram
1.2 Duct Connected Type
Connectors
PCB(1) (Control PCB)
PCB(2) (Display PCB)
Note:
Other designations
PCB(1) (Control PCB)
PCB(2) (Display PCB)
1)
S1
Connector for AC fan motor
2)
S7
Connector for AC fan motor
3)
S21
Connector for
centralized control
to 5 rooms
4)
S26
Connector for display PCB
5)
S32
Connector for heat exchanger thermistor
1)
S1
Connector for control PCB
1)
V1
Varistor
2)
JA
Address setting jumper
JB
Fan speed setting when compressor is OFF on thermostat
JC
Power failure recovery function
*
Refer to page 181 for more detail.
3)
LED A
LED for service monitor (green)
4)
FU1
Fuse
(3.15A)
1)
SW1 (S1W)
Forced operation ON/OFF switch
2)
LED1
LED for operation (green)
3)
LED2
LED for timer (yellow)
4)
LED3
LED for HOME LEAVE operation (red)
5)
RTH1 (R1T)
Room temperature thermistor
Summary of Contents for 2MKS40FV1B