![background image](http://html.mh-extra.com/html/daikin/2mks40fv1b/2mks40fv1b_service-manual_501074172.webp)
SiEN12-710A
Outdoor Unit
Removal Procedure
161
11
Detach the discharge
pipe thermistor.
"
Meet the edge of the
thermistor and the clip.
"
Be careful not to lose the clip
for the discharge pipe
thermistor.
12
Disconnect the
connector for the
thermistor ASSY. [S90]
[S90] : Thermistor ASSY
(Outdoor air, Heat
exchanger, Discharge
pipe)
13
Undo the wire clamp for
the thermistor ASSY
under the electrical box.
14
Loosen the screw on
the right side of the
electrical box.
Step
Procedure
Points
(R7586)
Clip for discharge pipe
thermistor
Discharge pipe thermistor
[S90]
(R7587)
(R7588)
Wire clamp
(R7589)