![background image](http://html.mh-extra.com/html/daikin/2mks40fv1b/2mks40fv1b_service-manual_501074137.webp)
Troubleshooting
SiEN12-710A
126
Service Diagnosis
Troubleshooting
Check No.04
Refer to P.146
Check No.06
Refer to P.149
Check No.07
Refer to P.150
Check No.09
Refer to P.151
(R7142)
Caution
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
Replace the fan motor.
Repair the connector or fan
motor lead wires.
Replace the heat exchanger
thermistor.
Replace PCB.
Replace the electronic
expansion valve or coil.
Replace the PCB.
Change the air outlet grille
position.
Clean the heat exchanger.
Change the installation
location.
Abnormal
Normal
Normal
Normal
Normal
Abnormal
Abnormal
Abnormal
Check No. 09
Check the outdoor fan.
Check No. 07
Check the installation
condition.
Judgment
Judgment
Check No. 06
Check the heat exchanger
thermistor.
Check No. 04
Check the electronic expansion valve.
Check the installation space.