![background image](http://html.mh-extra.com/html/daikin/2mks40fv1b/2mks40fv1b_service-manual_501074181.webp)
Outdoor Unit
SiEN12-710A
170
Removal Procedure
1.5 Removal of the Propeller Fan / Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the propeller fan
1
Loosen the washer
fitted nut (M10) by an
open-ended spanner to
remove the propeller
fan.
"
When assembling, align
mark of the propeller fan with
D-cut section of the motor
shaft.
2. Remove the fan motor
1
Disconnect the
connector [S70] for the
fan motor from the
PCB.
(R7618)
(R7619)
(R7620)
[S70]
(R7621)