SiEN12-710A
Main Functions
Function and Control
31
1.7 Night Set Mode
When the OFF timer is set, the Night Set circuit automatically activates.
The Night Set circuit maintains the airflow setting made by users.
The Night Set
Circuit
The Night Set circuit continues heating or cooling the room at the set temperature for the first
one hour, then automatically raises the temperature setting slightly in the case of cooling, or
lowers it slightly in the case of heating, for economical operations. This prevents excessive
heating in winter and excessive cooling in summer to ensure comfortable sleeping conditions,
and also conserves electricity.
Cooling
Operation
In case of FTKS25/35D, FTXS25/35E the temperature rises once.
Heating
Operation
Operation stops
at the set hours
Timer operation
Night Set Circuit ON
+ 0.5°C
temperature shift
+ 0.5°C temperature shift
Temperature setting remains the same
When outside temperature is normal and room
temperature is at set temperature
When outside temperature is high (27°C or higher)
1 hour
30 minutes
Temperature
s 1°C
Temperature
s 0.5°C
Temperature
setting
0,5°C
0,5°C
(R1361)
A
A
:
:
A
B
B
B
Temperature
s 0.5°C
Temperature
setting
+0.5°C
temperature shift
(R4421)
0.5°C
1 hour
Operation stops
at the set hours
Timer operation
Night Set Circuit ON
(R1362)
2°C
Timer operation Night
Set Circuit ON
Thermostat
setting
1 hour later
Summary of Contents for 2MKS40FV1B
Page 11: ...Introduction SiEN12 710A x ...
Page 12: ...SiEN12 710A List of Functions 1 Part 1 List of Functions 1 Cooling Only 2 2 Heat Pump 4 ...
Page 17: ...Heat Pump SiEN12 710A 6 List of Functions ...
Page 25: ...Heat Pump SiEN12 710A 14 Specifications ...
Page 111: ...Instruction SiEN12 710A 100 Operation Manual ...
Page 199: ...Wiring Diagrams SiEN12 710A 188 Appendix ...
Page 203: ...SiEN12 710A iv Index ...