ENGLISH
91
O1
Output 1 function
O2
Output 2 function
4.4
Initial start-up of multiple inverter system
Make electrical and hydraulic connections of the entire system as described in para 2.2 and para 4.2.
Switch on one inverter at a time and configure the parameters as described in chapter 5 taking care that when turning on one
inverter, all others are switched off.
After configuring all inverters individually, all can be switched on simultaneously.
4.5
Multi-inverter settings
When a multi inverter system is switched on, the addresses are assigned automatically and, by means of an algorithm, an inverter is
nominated as the settings leader. The leader decides on the frequency and order of start-up of each inverter in the series.
The settings mode is sequential (inverters start one at a time). When start-up conditions are enabled, the first inverter starts, and
when this reaches maximum frequency, the next one starts, and so on. The order of start-up is not necessarily ascending according
to the machine address, but depends on the hours of operation; see ET: Tempo di scambio par. 6.6.9.
When the minimum frequency FL is used, and there is only one inverter operative pressure surges may occur. Depending on the
case, pressure surges may be inevitable and may occur at the minimum frequency when this value, in relation to the hydraulic load,
causes a pressure level greater than the required value. On multi inverter systems, this problem remains limited to the first pump that
is started up, as on the subsequent pumps the situation is as follows: when the previous pump reaches the maximum frequency, the
next one starts up at the minimum frequency to then reach the maximum frequency. When the frequency of the pump at maximum is
reduced (obviously through to the minimum frequency limit) the pump activation overlaps, which while observing minimum frequency
rates, does not cause pressure surges.
4.5.1
Assigning the start-up order
Each time the system is activated, each inverter is associated a starting order. This setting establishes the order of inverter start-up.
The starting order is modified during use according to requirements, by the two following algorithms:
•
Reaching of maximum operating time
•
Reaching of maximum inactivity time
4.5.1.1
Maximum operating time
According to parameter ET (maximum operating time), each inverter has an hour counter, and the starting order is updated on the
basis of these values according to the following algorithm:
-
if at least half of the value ET is exceeded, priority is changed on the first shutdown of the inverter (switch to standby).
-
if the value ET is reached without stopping, the inverter stops unconditionally and this sets to the minimum restart priority
(switch during operation).
If parameter ET (maximum working time) is set to 0, exchange occurs on each restart
.
See ET: Tempo di scambio par 6.6.9.
4.5.1.2
Reaching of maximum inactivity time
The multi inverter system has an anti-stagnant algorithm that is aimed at maintaining pump efficiency and integrity of the pumped
liquid. It acts by enabling rotation of the pump starting order to ensure a delivery to all pumps of at least one minute of flow every 23
hours. This is implemented regardless of the inverter configuration (enabled or reserve). Priority switch envisages that the inverter
stationary for 23 hours is set to maximum priority in the starting order. This means that it is the first to be started up as soon as flow
delivery is required. The inverters configured as reserve have priority over the others. The algorithm terminates action when the
inverter has delivered at least one minute of flow.
After the anti-stagnant interval, if the inverter is configured as reserve, it is set to minimum priority to avoid premature wear.
4.5.2
Reserves and number of inverters involved in pumping
The multi inverter system reads how many elements are connected in communicating mode and calls this number N.
Summary of Contents for PWM 203
Page 13: ...ITALIANO 11 Figura 2 Fissaggio e distanza minima per la circolazione d aria...
Page 73: ...ENGLISH 71 Figure 2 Fixture and minimum clearance for air circulation...
Page 129: ...FRAN AIS 127 Figure 2 Fixation et distance minimum pour la circulation de l air...
Page 185: ...DEUTSCH 183 Abbildung 2 Befestigung und Mindestabstand f r die Luftzirkulation...
Page 244: ...ESPA OL 242 Figura 2 Fijaci n y distancia m nima para la circulaci n del aire...
Page 295: ...293 IEC 60634...
Page 296: ...294 1 6 1 1...
Page 300: ...298 1 2 5 2 1 2 1 2 2...
Page 301: ...299 2...
Page 302: ...300 2 2 3 3 15 2 2 1 4 2 2 1 1 PWM 203 202 201 3 1 LN 4 2 3...
Page 306: ...304 6 2 2 3 3 Press e Flow 7 A B C D...
Page 311: ...309 DC AC 50 60 8 6 2 1 5 36 36 12 3 3 3 3 2 13 7 11 8 11...
Page 313: ...311 9 MODE 1 SET 9 3 EEprom SET 6 SET MODE 3 1 11 3 2 1 2 3 2 1 MODE SET MODE 10...
Page 315: ...313 SO AE MP I1 1 I2 2 I3 3 I4 4 O1 1 O2 2 RF PW 11 3 2 2 13 SET 13 15 14...
Page 316: ...314 14 3 3 12 GO SB BL LP HP EC OC OF SC OT...
Page 318: ...316 4 4 1 Link 8 4 2 4 2 1 Link Link 16...
Page 322: ...320 4 4 2 2 4 2 5 4 5 ET 6 6 9 FL 4 5 1 4 5 1 1 ET ET ET ET 0 ET 6 6 9 4 5 1 2 23 23...
Page 359: ...NEDERLANDS 357 Afbeelding 2 Bevestiging en minimumafstand voor luchtrecirculatie...
Page 418: ...SVENSKA 416 Fig 2 Fasts ttning och min utrymme f r luftcirkulation...
Page 473: ...T RK E 471 ekil 2 Hava sirk lasyonu tesisat ve minimum a kl k...
Page 523: ...520 IEC 364 inverter...
Page 524: ...521 1 Inverter inverter inverter 6 inverter 1 1...
Page 528: ...525 1 2 1 1 inverter inverter 1 1 2 5 inverter 2 1 inverter 2 1 2 2 C...
Page 529: ...526 2...
Page 534: ...531 6 2 2 3 3 Press Flow 7 A B C D...
Page 539: ...536 DC V AC 50 60 Hz Vrms V 8 6 V 2 1 5 V 36 36 12V mA 3 3 3 3 mm 2 13 7 11 8...
Page 545: ...542 14 3 3 go Hz bar psi 12 GO SB BL LP HP EC OC OF SC OT...
Page 588: ...ROM N 585 Figura 2 Fixarea i distan a minim pentru circula ia aerului...
Page 635: ...01 20 cod 60198807...