DGS-3620-28SC:admin#show syslog
Command: show syslog
Syslog Global State: Enabled
DGS-3620-28SC:admin#
71-15
config syslog host
Description
This command is used to configure the syslog host configuration.
Format
config syslog host [<index 1-4> | all] {severity [emergency | alert | critical | error | warning |
notice | informational | debug| <level 0-7>] | facility [local0 | local1 | local2 | local3 | local4 |
local5 | local6 | local7] | udp_port <udp_port_number> | ipaddress [<ipaddr> | <ipv6addr>] |
state [enable | disable]}(1)
Parameters
<index 1-4>
- Enter the host index.
all
- Specifies all hosts.
severity
- (Optional) Specify the severity level supported: emergency, alert, critical, error,
warning, notice, informational, or debug.
emergency
- Specifies emergency messages.
alert
- Specifies alert messages.
critical
- Specifies critical messages.
error
- Specifies error messages.
warning
- Specifies warning messages.
notice
- Specifies notice messages.
informational
- Specifies informational messages.
debug
- Specifies debug messages.
<level 0-7>
- Enter a level between 0 and 7.
facility
- Some of the operating system daemons and processes have been assigned facility
values. Processes and daemons that have not been explicitly assigned a facility may use any
of the"local use" facilities or they may use the "user-level" facility. Those facilities that have
been designated are shown in the following:
local0
- User-defined facility.
local1
- User-defined facility.
local2
- User-defined facility.
local3
- User-defined facility.
local4
- User-defined facility.
local5
- User-defined facility.
local6
- User-defined facility.
local7
- User-defined facility.
udp_port
- Specifies the UDP port number.
<udp_port_number>
- Enter the UDP port number.
ipaddress
- Specifies the IPv4 address or IPv6 address of the host.
<ipaddr>
- Enter the IPv4 address of the host.
<ipv6addr>
- Enter the IPv6 address of the host.
state
- The syslog protocol has been used for the transmission of event notification messages
Summary of Contents for xStack
Page 1: ......
Page 553: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide 548 ...
Page 565: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide 560 ...
Page 1011: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide 1006 ...
Page 1120: ...xStack DGS 3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide 1115 ...