64
Expert-32T rev.03
FACTORY SETTINGS
P A R A M E T E R
F A C T O R Y
S E T T I N G
R A N G E O F
V A L U E S
T e m p e r a t u r e S e t P o i n t
7 5
o
F
( 2 3 . 9
o
C )
- 4 0 t o 1 0 0
o
F
( - 4 0 t o 3 7 . 8
o
C )
H e r d A g e
1 d a y
1 t o 2 5 0 d a y s
M i n i m u m
V e n t i l a t i o n
O n T i m e
1 m : 3 0 s
0 t o 9 9 m : 0 0 s
C y c l e T i m e
5 m : 0 0 s
0 t o 9 9 m : 0 0 s
C o o l i n g
O n t i m e
0
0 t o 9 9 m : 0 0 s
O f f t i m e
0
0 t o 9 9 m : 0 0 s
T u n n e l
V e n t i l a t i o n
F i r s t T u n n e l S t a g e
8
3 - 1 0
L a s t T u n n e l S t a g e
1 0
3 - 1 0
M i n i m u m A g e
2 0 d a y s
1 t o 2 5 0 d a y s
C u r t a i n O p e n i n g T i m e
3 0 s
0 t o 1 5 m : 0 0 s
M i n i m u m O u t s i d e
T e m p e r a t u r e
7 0 ° F
( 2 1 . 1 ° C )
- 4 0 t o 1 0 0 ° F
( - 4 0 t o 3 7 . 8
o
C )
V e n t D o o r s
H i g h P r e s s u r e S e t
P o i n t
0 . 0 6 "
0 . 1 t o 0 . 4 "
L o w P r e s s u r e S e t
P o i n t
0 . 0 4 "
0 t o 0 . 3 9 "
W i n t e r T e m p e r a t u r e
S e t P o i n t
5 . 0 ° F
( - 1 5 ° C )
- 4 0 t o 1 0 0 ° F
( - 4 0 t o 3 7 . 8
o
C )
S u m m e r T e m p e r a t u r e
S e t P o i n t
5 0 . 0 ° F
( 1 0 ° C )
- 4 0 t o 1 0 0 ° F
( - 4 0 t o 3 7 . 8
o
C )
O p e n i n g T i m e
1 5 s
0 t o 9 0 0 s
C l o s i n g T i m e
1 5 s
0 t o 9 0 0 s
O f f T i m e
3 0 s
0 t o 9 0 0 s
F a n D e l a y
3 0 s
0 t o 3 0 0 s
S t a g e L e v e l f o r
C l o s i n g V e n t D o o r s
8
F i r s t T u n n e l S t a g e t o
F a n s t a g e n u m b e r
S t a t i c P r e s s u r e A l a r m
D e l a y
3 0 0 s
0 t o 9 0 0 s
C l o c k
O u t p u t s
R u n n i n g T i m e
0
0 t o 1 5 h : 0 0 m : 0 0 s
Summary of Contents for Expert-32T
Page 1: ...Expert 32T Temperature Controller USER S MANUAL T...
Page 2: ......
Page 75: ......
Page 76: ...M 890 00074 rev 03 REV 01...