9
Expert-32T rev.03
Expert-32T
Room Temperature Display:
The display on the top right corner of the
faceplate shows the current room temperature averaged over all se-
lected room temperature probes or the static pressure.
LCD Display:
The LCD display on the left gives the current readings and
parameters to be adjusted when you
select a function. The three keys to
the right of the display are used to
edit parameters and step through
the display. When the parameters
for a given function cannot all be
presented at once on the display, arrows are displayed on the right hand
side to indicate that additional parameters can be displayed using the
arrow keys
. After 15 minutes of inactivity, the display
returns to the ROOM TEMPERATURE display.
Adjusting a Parameter:
A parameter can be adjusted when it is flashing
on the LCD display. Use the Edit key
to step through the param-
eters displayed. When the required parameter is flashing, use the arrow
keys next to the display to adjust the parameter.
To step to another display screen, it may be necessary to press
the Edit key several times to step through the remaining param-
eters displayed until the up- and down-arrows reappear to the
right of the display.
Output Status LEDs:
The LEDs on the right of the control panel give the
status of each output. When the LED is turned on, the output is acti-
vated; when the LED is turned off, the output is deactivated. In the
case of the fan stages, a flashing LED indicates that the activation of the
fan stage is delayed by the opening of the curtain.
Room 76.9°F
Probes: 1 2 3