21
Expert-32T rev.03
Expert-32T
Relays 1-8
12t45678
Heater 4 Probes
1234
Use some relays
on timer? NO
Relays with Timer on Fan Stages 2-10
: For these fan stages, the user
can configure certain relays to operate in timer mode for cooling while
other relays operate in on-off mode. Fan stage 1 is used for minimum
ventilation. When you configure this stage, the message «Stage used for
min. ventilation» is displayed to remind the user that relays for the stage
cannot be configured in timer mode.
Press the Edit key and set the
timer mode to YES to configure
certain relays in timer mode for
cooling.
Press the down-arrow key to map
the relays. If timer mode is set to
YES, the user can choose between
ON, OFF and timer when selecting
a relay. When a relay is in timer
mode, the relay digit is replaced
with the letter t.
PROBE ASSIGNMENTS
Probes must be individually selected
for each heater. Use the arrow keys
to select a heater stage. The probes
assigned to the heater appear flashing
on the display. Press the Edit key and
use the arrow keys to enable or disable
each probe individually for the heater.