43
Expert-32T rev.03
Expert-32T
Press the Edit key. The minimum age value flashes on the display.
Use the arrow keys to adjust the minimum age to the desired value.
3
Adjusting Minimum Outside Temperature
The minimum outside temperature is used to prevent tunnel ventilation
from being used when the outside temperature is too cold.
Set the function to
START/STOP TEMPERATURE
using the menu
select buttons. The start and stop temperatures for Heater 4 are
displayed and the Heater 4 LED on the right flashes.
Use the output select buttons to
select
TUNNEL CURTAIN – OPEN.
The corresponding LED on the
right of the front panel flashes.
Press the down-arrow key twice to
display the minimum outside
temperature.
Press the Edit key. The minimum outside temperature value flashes
on the display. Use the arrow keys to adjust the minimum tempera-
ture to the desired value.
4
Adjusting Curtain Operating Times
The curtain operating time is the time during which the curtain opens
when a new tunnel stage is activated or closes when a tunnel stage is
deactivated. This value is adjusted for each tunnel stage to control static
pressure changes between tunnel stages*. When the temperature
reaches the first tunnel stage starting temperature, the tunnel stage is
delayed until half of the curtain operating time has elapsed (up to 30
seconds). Operating times range from 0 minutes, 0 seconds to 15
minutes, 59 seconds.
1st stage: 9
100% opened: 10
Minimum outside
Temp: 70.0°F
*
If you do not want to control static pressure in this way, set the first and fully
opened tunnel stages to the same value.