33
Expert-32T rev.03
Expert-32T
2
Activating / Deactivating Minimum Ventilation Curve
Set the function to
MIN. VENTILATION / CURVE
using the menu
select buttons. The current on time, cycle time and curve on/off
state is displayed.
If the curve is OFF, press the Edit key five times until the on/off
state of the curve flashes. Use the arrow keys to activate the
curve.
If the curve is ON, press the Edit key once until the on/off state of
the curve flashes. Use the arrow keys to deactivate the curve.
3
Viewing Current Timer Settings and Day Number
When the minimum ventilation curve is activated, the current timer
settings and day number can be viewed at any time. The current day
number can also be adjusted in order to move forward or backward on
the curve.
Note that the day number used by the curve is defined by the herd
age value which is also used by the temperature curve.
Set the function to
MIN. VENTILATION / CURVE
using the menu
select buttons. The current on time, cycle time, curve on/off state is
displayed.
Set the function to
AGE
using the menu select buttons. The current
herd age is displayed.
Press the Edit key. The age value flashes on the display.
Use the arrow keys to set the age to the desired value.