49
Expert-32T rev.03
Expert-32T
6
Adjusting Stage Level for Closing Vent Doors
When the stage defined by this parameter is reached, the vent doors are
closed no matter what the static pressure is.
Set the function to
VENT DOORS
using the menu select buttons. The
high and low pressure set points for the winter season are displayed.
Press the down-arrow key eight
times. The stage level is displayed.
Press the Edit key. The stage level flashes on the display. Use the
arrow keys to adjust the stage level to the desired value.
7
Adjusting Static Pressure Alarm Delay
When the static pressure is outside the limits defined by the pressure set
points, the controller waits for this delay to elapse before setting off a
static pressure alarm. The alarm delay can be adjusted from 0 to 900
seconds.
Set the function to
VENT DOORS
using the menu select buttons. The
high and low pressure set points for the winter season are displayed.
Press the down-arrow key nine
times. The alarm delay is displayed.
Press the Edit key. The alarm delay flashes on the display. Use the
arrow keys to adjust the delay to the desired value.
Close vent door
at stage: 9
Pressure alarm
Delay: 300sec