42
Expert-32T rev.03
Expert-32T
1
Adjusting First and Fully Opened Tunnel Stages
Fan stages 1 and 2 cannot be tunnel stages. The first and fully opened
tunnel stages must be equal or in increasing order. Note all fan stages
above the first tunnel stage are considered tunnel stages.
Set the function to
START / STOP TEMPERATURE
using the menu
select buttons. The start and stop temperatures for Heater 4 are
displayed and the Heater 4 LED on the right flashes.
Use the output select buttons to
select
TUNNEL CURTAIN – OPEN
.
The corresponding LED on the
right of the front panel flashes.
Press Edit key. The first tunnel stage flashes. Use the arrow keys to
adjust the first tunnel stage to the desired value.
Press Edit key. The fully opened tunnel stage flashes. Use the arrow
keys to adjust the fully opened tunnel stage to the desired value.
2
Adjusting Minimum Age
The minimum age is used to prevent tunnel ventilation from being used
when the animals are too young. The value ranges from 1 to 250 days.
The tunnel stages do not operate until the herd age reaches this value.
Set the function to
START/STOP TEMPERATURE
using the menu
select buttons. The start and stop temperatures for Heater 4 are
displayed and the Heater 4 LED on the right flashes.
Use the output select buttons to select
TUNNEL CURTAIN – OPEN.
The corresponding LED on the right of the front panel flashes.
Press the down-arrow key to
display the minimum age.
1st stage: 9
100% opened: 10
Minimum
age: 20