Operating
Keys
Display
1
.
Press
【
LINE
】
in the Meas mode to enter
the menu mode come in <S-O LINE>
S-O LINE
menu.
1.Def.base line
Select “4. Stn.data” to input the
2.Point
instrument station data. Select “5.Stn.
3.Line
orient” to set the azimuth angle. Select
↓4.Stn.data
【LINE】
“6.Ins.h&Tgt.h”to input the instrument
height and the prism height.
(
Please see
“12.1 Inputting instrument station
coordinate”, “12.2 Azimuth angle setting”,
“12.3 inputting the height of instrument
and prism”
)
.
2. Press
【
】
to select “Def. baseline”.
Input the coordinate of the baseline
Baseline origin
starting point.
N<m>:
0.000
z
To recall the coordinate data registered in the
memory, press
【
READ
】
.
(
Please see “12.1.2
Reading in registered coordinate data”
)
.
E<m>:
0.000
Z<m>:
0.000
【
】
z
Press
【
REC
】
to record the coordinate data in
the memory.
READ
REC
OK
3. Press
【
OK
】
after inputting the data, then
input the azimuth and the grade of the
【Baseline direc.】
baseline. Press
【
OK
】
to finish the
Direc:
0.0000
definition of baseline.
Slope: 0.0000﹪
z
When
【
PT2
】
is pressed
,
the azimuth and
the grade of the baseline can be calculated
by inputting the coordinate of the second
point at the baseline.
【OK】
PT2
OK