5. When the two known points have been
input and measured, the list of the known
Resection
points is displayed.
01:PT-01
z
Press
【
】
/
【
】
to move the cursor and
select the known point.
02:PT-02
z
Press
【
ADD
】
to add a known point for
resection.
z
Press
【
REOBS
】
to reenter or re-observe
the known point selected.
z
Press
【
CALC
】
to start calculations.
z
Press
【
Y/N
】
to make the known point
selected joining for calculation or not.
ADD
REOBS Y/N
CALC
6
.
Press
【
CALC
】
. The instrument station
Resection
coordinates are calculated and displayed.
N0 100.003m
z
Press
【
REC
】
to store the results in the
memory.
E0 99.998m
【CALC】
Z0 0.001m
z
Press
【
REC
】
to accept the calculated
results as the new station coordinates.
REC
OK
7. Press
【
OK
】
to set the instrument station
Resection
coordinates, then the azimuth angle of
Set H angle:
the first known point as the backsight
HAR:131°17′46″
point is calculated and displayed.
Take 1st target?
Sight the known point 1
,
press
【
YES
】
【OK】
to set the azimuth angle and return to the
Meas Mode.
z
Press
【
SKIP
】
to return the Meas mode
without setting the azimuth angle.
SKIP
YES
58
Summary of Contents for CST202
Page 1: ...CST202 CST205 INSTRUCTION MANUAL Electronic Total Station...
Page 117: ......