
2. Prism constant correction value
Reflective prisms each have their prism constant (PC). Before measurement, you must set the
prism constant correction value of the prism you are using. This instrument’s prism constant
correction value has been set to “0” by default. (CST Prisms are either “0” or “-30”)
3. Distance measurement mode
z
Fine Single measurement (Fine s.)
z
Fine Repeat measurement
(Fine r.)
z
Fine Average measurement (Fine AVG)
z
Rapid Single measurement (Rapid s.)
z
Rapid Repeat measurement (Rapid r.)
z
Tracking measurement
(Tracking)
Operating
Keys
Display
1
.
From the first page of the Meas mode.
MEAS
H
ZA 99°43
′
13
″
HAR 120°21
′
12
″
P1
DIST
SHV
HSET
EDM
2
.
Press
【
EDM
】
to Enter the EDM Setting
Screen.
EDM set
Mode:
Fine r.
【
EDM
】
C&R crn: OFF
PC:
0
P1
OK
3
.
Press
【
】
/
【
】
to change the
distance measurement mode to
EDM set
Rapid Repeat measurement mode.
Mode
Rapid r.
【
】
C&R crn
OFF
【
】
PC
0
P1
OK
25
Summary of Contents for CST202
Page 1: ...CST202 CST205 INSTRUCTION MANUAL Electronic Total Station...
Page 117: ......