Example 1
:
Input file name “FTS”
(
1
)
Press
【
SFT
】
to come in the inputting letters mode, there will be
the letter “a” displayed on the right of the screen.
(
2
)
Press
【
2
】
three times, and then input the “F”
。
(
3
)
Press
【
】
to move the curser to the right, press
【
7
】
twice
and input the letter “T”.
(
4
)
Press
【
】
to move the curser to the right, press
【
7
】
once
and input the letter “S”.
(
5
)
Press
【
】
to confirm it.
Select a job
a
JOB
:
FTS
LIST
Example 2
:
Set the unit of air pressure as “mmHg”
:
(1) In the config. mode , Press
【
】
/
【
】
to move the cursor
to “4.Unit”. Press
【
】
to confirm it.
(2) Press
【
】
/
【
】
to move the cursor to “Pres. unit”
(3) Press
【
】
/
【
】
to move the cursor and select the unit
“mmHg”.
(4) Press
【
】
to confirm it and then exit.
CONFIG
1.Obs. condition
2.Instr. const
3.Key function
4.Unit
Ang. unit
*deg
Dist. unit
*m
Temp. unit
*℃
Press. unit
mmHg
8
Summary of Contents for CST202
Page 1: ...CST202 CST205 INSTRUCTION MANUAL Electronic Total Station...