Operating
Keys
Display
5. After the coordinates are entered, press
[OK].
The distance and the horizontal
angle of the point to be set out are
calculated and displayed on the screen.
z
If the prism height has to be changed.
Press
【
HT
】
and re-enter the prism
height before the measurement.(Please
see “12.3 inputting the height of
instrument and prism”)
【
OK
】
S-O H & HA
H<m>:
226.4854
HA:
79°43′37″
OK
CRD
HT
6. Press
【
OK
】
to enter the Set Out Coord
S-O Coord.
observation screen.
dN
dE
dZ
【
OK
】
EDM
MODE
OBS
7. Press
【
】
to enter the setting-out
leading screen. Following step 7 to 10 in
“13.1 Distance setting-out measurement”,
complete the plane coordinates
setting-out. Then observe the difference
height between the target and the
required point which displayed on the
fourth line.
z
The Arrows mean the following:
:
move the prism up ward
:
move the prism down ward
S-O Coord.
←→
0°00′00″
↑↓
0.001m
【
】
0.143m
EDM
MODE
DIFF
OBS