17.1 Calculating the station coordinate by measuring 2 known point
Keys Display
Operating
1
.
In the third page of the Meas Mode, press
【
RESE
】
to perform this function.
Resection/PT-01
z
Selecting “3.Resection” in the menu
N﹤m﹥:
mode can also perform this function.
E﹤m﹥:
【RESE】
Z﹤m﹥:
READ
REC
OBS
2. Input the coordinates of the first known
point. Then sight it and press
【
OBS
】
to
Resection
start measurement.
S:
557.259m
Press
【
STOP
】
to stop measurement.
ZA:
97°31′05″
【
OBS
】
HAR:
351°15′06″
STOP
3. The measurement results are displayed
on the screen. Input the prism height of
S 557.259m
the known point.
ZA: 97°31′05″
HAR: 351°15′06″
Tgt.h<m>:
0.000
CE
OK
4. Press
【
OK
】
and then input and measure
Resection/PT-02
the second known point in the same way.
N﹤m﹥:
【
OK
】
E﹤m﹥:
Z﹤m﹥:
READ
REC
OBS
57