3
.
Select “1. Tilt offset” and press
【
】
Tilt offset
to start adjustment.
z
Pressing
【
0SET
】
can set horizontal angle
to 0.
【
】
TILT -43
HAR 350°19′22″
<Step1> Take F1?
CE
0SET
OK
4. Sight the target point in Face 1. Wait for the
display of tilt value to stabilize, and then
press
【
OK
】
.
z
Press
【
CE
】
to cancel the last operation
and redo it.
【OK】
TILT offset
TILT 25
HAR 170°19′26″
<Step2> Take F2?
CE
0SET
OK
5. Loosen the horizontal clamp, rotate the top
of the instrument through 180°, and then
sight the same target in Face 2. Wait for the
display of tilt value to stabilize, and then
press
【
OK
】
. If there’s no error in operation,
the new offset value of tilt zero is displayed.
Tilt offset
Offset: -9
Set?
【OK】
CE
OK
6
.
Press
【
OK
】
to accept the new value for
correction and return to <Instr. ADJ>
Instr. ADJ
Menu.
1.Tilt offset
【OK】
z
Press
【
CE
】
to discard the value and
repeat the procedures mentioned above.
2.V0 & Coll. crn
3.Instr. const
7. Press
【
ESC
】
to return to the Meas mode
and the new correction constant is in effect.
【ESC】
MEAS
H
ZA
99°43′13″
HAR
350°19′23″
P1
DIST
SHV
HSET
EDM
96
Summary of Contents for CST202
Page 1: ...CST202 CST205 INSTRUCTION MANUAL Electronic Total Station...
Page 117: ......