Operating
Keys
Display
1
.
On the third page of the Meas Mode
Screen, press
【
S-O
】
to enter the <S-O>
menu.
z
Selecting “2. S-O” in the Menu Mode
S-O
1.S-O data
2.S-O obs.
will perform the same function.
3.Stn.data
2. Select “3. Stn.data” to input the
instrument station data. Select “4. Stn.
orient” to set the azimuth angle. Select
↓4.Stn.orient
“5. Ins.h&Tgt.h”to input the instrument
height and the prism height.
(
Please see
“12.1 inputting instrument station
coordinate”, “12.2 Azimuth angle setting”,
“12.3 inputting the height of instrument
and prism”
)
,
【S-O】
3
.
Then select “1. S-O data” and press
【
】
to enter the setting-out data
S-O H & HA
screen.
H<m>:
【
】
HA:
CRD
OK
4
.
Press
【
CRD
】
.<S-O Coord.> is displayed.
Input the coordinates of the point to be set
out. (Staked out)
S-O Coord.
Np<m>:
z
When
【
READ
】
is pressed, stored
coordinates can be recalled and used as
set-out coordinates.
(
Please see “12.1.2
Reading in registered coordinate data”
)
Ep<m>:
Zp<m>
【
CRD
】
z
Press
【
H&HA
】
to enter the distance
set-out mode.
z
Press
【
REC
】
to record the input
coordinate data.
READ
REC
H&HA
OK
41
Summary of Contents for CST202
Page 1: ...CST202 CST205 INSTRUCTION MANUAL Electronic Total Station...
Page 117: ......