72
F2.01
Motor rated power
0.4
~
6553.5KW
【
Depend on
model
】
F2.02
Motor rated frequency
0.01Hz
~
F0.07
【
50.00Hz
】
F2.03
Motor rated speed
0
~
60000rpm
【
Depend on model
】
F2.04
Motor rated voltage
50
~
460V
【
Depend on model
】
F2.05
Motor rated current
0.1A~6553.5A
【
Depend on model
】
Note: In order to achieve superior performance, please set these parameters
according to motor nameplate, and then perform autotuning.
The inverter provides parameters autotune.Correct parameters autotune is from the
right setting of parameter of motor.
The power rating of inverter should match the motor.If the bias is too big,the control
performances of inverter will be deteriorated distinctly.
Note:Reset F2.01 can initialize F2.06-F2.10 automatically.
Code
Name
Setting Range
F2.06
Motor stator resistance
0
~
65.535
Ω
【
Depend on model
】
F2.07
Motor rotor resistance
0
~
65.535
Ω
【
Depend on model
】
F2.08
Motor stator & rotor inductance
0
~
655.35mH
【
Depend on
model
】
F2.09
Motor stator & rotor mutual
inductance
0
~
6553.5mH
【
Depend on
model
】
F2.10
Motor no-load current
0.1
~
6553.5A
【
Depend on
model
】
After autotuning,the value of F2.06
一
F2.10 will be automatically updated.These
parameters are the basic parameters for high performance V/F control which have direct
impact to the control performance.