Note:Do not change these parameters.
6.4 F3 Group: Vector control
Code
Name
Setting Range
F3.00
ASR proportional gain 1
1
~
3000
【
1000
】
F3.01
ASR integral time 1
1
~
8000
【
300
】
F3.02
ASR switching point 1
0.00Hz
~
F3.05
【
5.00Hz
】
F3.03
ASR proportional gain 2
1
~
3000
【
800
】
F3.04
ASR integral time 2
1
~
3000
【
200
】
F3.05
ASR switching point 2
F3.02
~
F0.07
【
10.00Hz
】
The above parameters are only valid for vector control.ASR PI parameters is decided
by F3.00 and F3.01 when output frequency is less than F3.02.ASR PI parameters is
decided by F3.03 and F3.04 when output frequency is greater than F3.05.When output
frequency is between F3.02 and F3.05,ASR PI parameters obtained by two groups of
parameters of the linear change,please refer to following figure.
Fig.6-5 PI parameter diagram