100
1:After the compensation
6.9 F8 Group: Auxiliary function
Code
Name
Setting Range
F8.00
Acceleration time 2
0.1
~
3600.0S
【
20.0S
】
F8.01
Deceleration time 2
0.1
~
3600.0S
【
20.0S
】
F8.02
Acceleration time 3
0.1
~
3600.0S
【
20.0S
】
F8.03
Deceleration time 3
0.1
~
3600.0S
【
20.0S
】
F8.04
Acceleration time 4
0.1
~
3600.0S
【
20.0S
】
F8.05
Deceleration time 4
0.1
~
3600.0S
【
20.0S
】
ACC/DEC time can be selected among F0.11
,
F0.12 and the above three
groups.Their meanings are the same. Please refer to the relative instructions of F0.11 and
F0.12.
Select the ACC/DEC time 0
~
3 through the different combination of the multifunction
digital terminals when the inverter runs.
Code
Name
Setting Range
F8.06
JOG reference
0.00
~
50.00
【
5.00Hz
】
F8.07
JOG acceleration time
0.1
~
3600.0S
【
Depend on
model
】
F8.08
JOG deceleration time
0.1
~
3600.0S
【
Depend on
model
】