103
Fig.6-17 Traverse operation diagram
Traverse range:The traverse running is limited by upper and low frequency.
The traverse range relative to the center frequency: traverse range AW=center
frequency*traverse range F08.12.
Sudden jumping frequency=traverse range AW *sudden jumping frequency range
F08.13.When run at the traverse frequency, the value which is relative to the sudden
jumping frequency.
The raising time of the traverse frequency:The time from the lowest point to the highest
one.
The declining time of the traverse frequency:The time from the highest point to the
lowest one.
Code
Name
Setting Range
F8.16
FDT1 level
0.00 Hz
~
F0.07
【
50.00Hz
】
F8.17
FDT1 lag
0.00~10.00Hz
【
1.00Hz
】
F8.18
FDT2 level
0.00 Hz
~
F0.07
【
50.00Hz
】
F8.19
FDT2 lag
0.00~10.00Hz
【
1.00Hz
】
Setting the testing-value of the output frequency and the lag value of The output action
removing.as shown in following figure: