96
After the password has been set and becomes valid,the user can not access menu if
the user's password is not correct.Only when a correct user's password is input,the user
can see and modify the parameters.Please keep user's password in mind.The password
protection becomes valid in 1 minute after quitting from the Code editing state.Press
PRG/ESC again to the Code editing state,“0.0.0.0.0.”will be displayed.Unless using the
correct password,the operators cannot enter it.
Code
Name
Setting Range
F7.02
Change Parameter display
0
~
1
【
0
】
0:Display all parameter
1:Display amended parameter only
Unmodified Parameters will be hidden.
Code
Name
Setting Range
F7.03
QUICK/JOG function selection
0
~
3
【
0
】
QUICK/JOG is a multifunctional key, whose function can be defined by the value.
0:Jog.Press QUICK/JOG ,the inverter will jog.
1: FWD/REV switching.Press QUICK/JOG ,the running direction of inverter will
reverse.It is only valid When the keyboard control.
2:Clear UP/DOWN setting.Press QUICK/JOG ,the UP/DOWN setting will be cleared.
3:Run command channel switching (switch between terminal and keyboard).
Code
Name
Setting Range
F7.04
STOP/RST function selection
0
~
3
【
2
】
This Code defines the STOP/RST STOP function effective choice.
0:Valid when keypad control