93
1
Reference frequency
0
~
Maximum frequency
2
Running speed
0
~
2*rated synchronous speed of
motor
3
Output current
0
~
2*inverter rated current
4
Output voltage
0
~
1.5*inverter rated voltage
5
Output power
0
~
2*rated power
6
Setting torque
0
~
2*rated current of motor
7
Output torque
0
~
2*rated current of motor
8
AI1 input
0
~
10V/0
~
20mA
9
AI2 input
0
~
10V/0
~
20mA
10
HDI input
0.1Hz
~
50.000kHz
Code
Name
Setting Range
F6.09
AO1 lower limit
0.0
~
100.0%
【
0.0%
】
F6.10
AO1 lower limit corresponding output
0.00
~
10.00V
【
0.00V
】
F6.11
AO1 upper limit
0.0
~
100.0%
【
100.0%
】
F6.12
AO1 upper limit corresponding output
0.00
~
10.00V
【
10.00V
】
These parameters determine the relationship between analog output voltage/current
and the corresponding output value. When the analog output value exceeds the range
between lower limit and upper limit, it will output the upper limit or lower limit.