TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–30
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
Summary
Fault Status
N/A
1 byte
Query only.
Indicates the condition of the summary fault relay.
Where:
0 = Not Faulted (SumFLT_COM J6 pin K is not connected
to SumFLT_NC J6 pin M)
1 = Faulted (SumFLT_COM J6 pin K is connected to
SumFLT_NC J6 pin M)
Example:
<1/SFS?
>0001/SFS=0’cr’’lf’
SFS=
SFS?
SFS=x
(See
description
for details of
arguments)
SNMP
Authenticatio
n Trap
Enable
SNA=
1 byte
Command or Query.
SNMP Authentication Trap Enable
0=Disabled
1=Enabled
Example:
<1/SNA=0
SNA=
SNA?
SNA?
SNA=x
(See
description
for details of
arguments)
SNMP
Enable
SNM=
1 byte
Command or Query.
SNMP Enable.
0=Disabled
1=Enabled
Example:
<1/SNM=0
SNM=
SNM?
SNM?
SNM=x
(See
description
for details of
arguments)
Serial
Number
N/A
9 bytes
Query only.
Used to Query the unit’s nine-digit serial number in the form
of SNO=xxxxxxxxx,
Where:
xxxxxxxxx is the unit’s nine-digit serial number.
Note
: This command is functionally identical to RSN.
Example:
<1/SNO?’cr’
>0001/SNO=072282040’cr’’lf’
SNO=
SNO?
SNO=xxxxx
xxxx
(See
description
for details of
arguments)