TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–25
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
PFAN2 = PS Fan #2 Speed in Percent
PFAN3 = PS Fan #3 Speed in Percent
PS40V = +40V Power Supply
PS40I = +40V Current
PS24I = +24V Power Supply
PS10V = +10V FET Voltage
PS10I = +10V FET Current
P5V8T = +5.8V Voltage
RF Module:
PS24V = +24V Fan Voltage
PS13V = +13.5V Voltage
RP5V8 = +5.8V Power Supply
RN5V8 = -5.8V Power Supply
RFAN1 = RF Fan #1 Speed in Percent
RFAN2 = RF Fan #2 Speed in Percent
RFAN3 = RF Fan #3 Speed in Percent
FWPWR = Module RF Forward Power in dBm
INPWR = System RF Input Power in dBm
RVPWR = System RF Reverse Power in dBm
ATEMP = Module Heatsink Temperature in deg C
OTEMP = Outdoor Temperature in deg C
ETEMP = Exhaust Temperature in deg C
Example:
<1/RMS?
>1/RMS=
>1/RMS=
PFAN1=094.0
PFAN2=095.0
PFAN3=096.0
PS40V=039.9
PS40I=067.0
PS24I=022.0
PS10V=010.1