TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Introduction
1–9
MN-TRP1000-OD
Para.
Description
Specification
1.5.1.19.2
4 kHz to 500 kHz
-20 (1.15 + log f), where f is in kHz
1.5.1.19.3
Above 500 kHz
-77 dBc maximum
1.5.1.20
Phase Noise
(IESS 308/309) -10dB
1.5.1.21
Noise & Spurious
-70 dBc
The sum of the fundamental and each harmonic
component of the alternating (AC) line frequency
shall not exceed -40 dBc.
1.5.1.22
Intermodulation Products for two equal
carriers anywhere in the Frequency Range
spaced 3 MHz apart with each carrier set to
the RF output power shown in paragraphs
1.5.1.22.1 to 1.5.1.22.2.
3
rd
order IM products measured relative to either
desired carrier at the RF output
1.5.1.22.1
Each carrier set 6 dB below rated power
-17 dBc
1.5.1.22.2
Each carrier set 9 dB below rated power
-25 dBc
1.5.1.23
Spectral re-growth @ QPSK +/- 1 to 1.5
Symbol Rate offset
-25 dBc minimum at any power up to 1 dB below
rated output power
1.5.1.24
RF Output Power Monitor
Coupling relative to RF Output: 50 dB, nominal
Front panel Connector: Type-N, Female
Front Panel Marking:
“OUTPUT SAMPLE”
1.5.2
Prime Power Requirements
Table 1-2. Prime Power Requirements
Para.
Description
Specification
1.5.2.1
Type
Single phase, Three -wire
1.5.2.2
AC Voltage
200-250 VAC
1.5.2.3
Frequency
47 to 63 Hz
1.5.2.4
Power Consumption
4500 VA maximum @ 1.0 kW output
1.5.2.5
Inrush Current
144A peak
1.5.2.7
Ground Leakage Current
2 mA AC maximum
1.5.2.8
Power Interruption
20 msec min without performance degradation
1.5.2.9
EMC Conducted and Radiated
EN55022-Level A
FCC Part 15 Class A