TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–20
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
Mute State
MUT=
1 byte
Command or Query.
Mute the unit,
Where:
0 = Disable (Not Muted)
1 = Enable (Muted)
2 = Aux Mute (Muted) [Query Only, AUX]
Example:
<1/MUT=1’cr’
>0001/MUT=1’cr’’lf’
Default Value: 0
MUT=
MUT?
MUT*
MUT?
MUT=x
(Same
format as
command
arguments)
Number of
Unread
stored Events
N/A
3 bytes
Query only.
Unit returns the Number of stored Events, which remain
Unread in the form of xxx.
Example:
<1/NUE?’cr’
>0001/NUE=126’cr’’lf’
NUE=
NUE?
NUE=xxx
Number of
Unread
stored
Statistics
N/A
3 bytes
Query only.
Unit returns the Number of stored Statistics, which remain
Unread in the form of xxx.
Example:
NUS=126
NUS=
NUS?
NUS=xxx
Part Number
N/A
96 bytes
alphanumeric
Query Only
The PNM query will return the DOTCODE string that was
loaded into the unit.
Example:
<1/PNM?
>0001/PNM=TRP0.0000000200’cr’’lf’
PNM=
PNM?
PNM *
PNM?
PNM=x….x
(See
description
for details of
return
string)
Retrieve
Alarm Status
N/A
Variable #
bytes
Query only.
The unit returns the alarm state for the following sections:.
RAS?
RAS=
RAS?
RAS=x….x
(See
description
for details of
arguments)