TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Updating Firmware
3–9
MN-TRP1000-OD
2. Check that the transfer completed successfully.
3. Verify the file transfer.
a. Reboot the unit:
•
Disconnect the power source from the TRP1000-4450.
•
Re-energize the TRP1000-4450. The unit will reboot using the updated firmware
image.
b. To verify that the new file has loaded, use the firmware version verification procedure
outlined in Section 3.2, Step 1.
The TRP1000 -4450 is now operating with its latest firmware. The serial-
based firmware update process is now complete.
3.4.2
Perform the Ethernet-based FTP Upload Procedure
1. Use Command-line to send a
“PING”
command to confirm proper connection and
communication between the user PC and the TRP1000-4450.
a. If the IP Address of the TRP1000-4450 is still not known:
•
Via Telnet Remote Control –
Type the “
<1/IPA?”
remote query (without quotes) at
the command prompt. The TRP1000-4450 returns the configured IP Address:
>0001/IPA= xxx.xxx.xxx.xxx
•
Via the TRP1000-4450 Web Server Interface –
View the
IP Address/Range
entry in
the
Network Maintenance
section of the ‘
Admin | Access
’ page: