TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–14
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
Hardware ID
N/A
1 byte
Query only:
Returns the value of the Hardware ID byte.
Example:
<0001/HID?’cr’
>0001/HID=0’cr’’lf’
HID=
HID?
HID=x
High Power
Threshold
HPT=
5 bytes
Command or Query.
This command allows the user to set the threshold for the
high forward power alarm/fault. If the forward power rises
above the specified value, the alarm/fault will be indicated.
HPT=xx.xx,
Where:
xx.xx = a real number between 48.00 and 64.00 dBm.
Example:
<1
/
HPT=63.00’cr’
>0001/HPT=’cr’’lf’
HPT=
HPT?
HPT*
HPT?
High Power
Threshold
Initialize
Events
Pointer
IEP=
None
Command only.
Resets internal pointer to allow RNE? Queries to start at the
beginning of the stored events log.
Example:
<1
/
IEP=’cr’
>0001/IEP=’cr’’lf’
IEP=
IEP?
IEP*
N/A
N/A