TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–28
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
Read Next 5
Statistics
N/A
436 bytes,
alpha-
numeric
Query only.
Returns the next five unread statistics stored in the statistics
log.
Returns 5 lines with the following format:
mm-dd-
yy;HH:MM:SS;a;b;c;dd.dd;ee.ee;ff.ff;gg.gg;hh.hh;ii.ii;jj.jj;kk.kk
;ll.ll;mm.mm;nn.nn;
Where:
mm-dd-yy = entry date
HH:MM:SS = entry time
a = amplifier enable state
b = mute enable state
c = summary fault state
dd.dd = RF attenuation
ee.ee = input power monitor
ff.ff = forward power monitor
gg.gg = reverse power monitor
hh.hh = outside temp
ii.ii = system 40V rail
jj.jj = RF 10V rail
kk.kk = RF 40I current
ll.ll = RF 10I current
mm.mm = heatsink temp
nn.nn = exhaust temp
RNS=
RNS?
RNS=x….x
(See
description
for details of
arguments)
Reverse
Power
Threshold
RPT=
5 bytes
Command or Query.
Sets the power threshold used to generate a reverse power
threshold alarm or fault condition (depending on the MSK
state) Format xx.xx,
Where:
xx.xx = the reverse power threshold level in dBm
RPT=
RPT?
RPT=xx.xx