TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–16
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
Gateway
Address
IPG=
15 bytes
Command or Query.
Used to set the Gateway IP address for the 10/100 Base Tx
Ethernet management port, in the format:
xxx.xxx.xxx.xxx,
Where:
xxx.xxx.xxx.xxx is the IP address
Example:
<1
/
IPG=192.168.001.005’cr’
>0001/IPG=’cr’’lf’
Default Value:
192.168.001.005
IPG=
IPG?
IPG*
IPG?
IPG =
xxx.xxx.xxx.
xxx
Initialize
Statistics
Pointer
ISP=
None
Command only.
Resets internal pointer to allow RNS? Queries to start at the
beginning of the statistics log.
Example:
<1/ISP=’cr’
>0001/ISP=’cr’’lf’
ISP=
ISP?
ISP*
N/A
N/A
Lamp Test
LAM=
1 byte
Command or Query.
Lamp test mode,
Where:
0 = Disable
1 = Enable (all front panel LEDs are lit)
Example:
<0001/LAM=1’cr’
>0001/LAM=1’cr’’lf’
Default Value: 0
LAM=
LAM?
LAM=x
Retrieve next
5 unread
Stored
Alarms
N/A
145 bytes
Query only.
See RNE query.
LNA=
LNA?
See RNE
query