TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–34
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
Temperature
N/A
7 bytes
Query only.
Returns the specified temperature.
Where:
0 = RF Module #1 Heatsink Temp
1 = RF Module #1 Inlet Temp
2 = RF Module #1 Exhaust Temp
Example:
<1/TMP?0’cr’
>0001/TMP=+052.27’cr’’lf’
TMP=
TMP?
TMP=x
(See
description
for details of
arguments)
Retrieve
Number of
unread
Stored
Alarms
N/A
2 bytes
Query only.
Returns the number of stored events, which remain unread in
the alarm log.
Example reply:
<1/TNA? ’cr’
>0001/TNA=14’cr’’lf’
TNA=
TNA?
TNA=xx
(See
description
for details of
arguments)
Total Number
of Events
N/A
2 bytes
Query only.
Returns the number of unread entries in the stored events
log.
Example:
<1/TNE? ’cr’
>0001/TNE=14’cr’’lf’
TNE=
TNE?
TNE=xx
(See
description
for details of
arguments)