TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–32
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
Set Statistics
Interval
SSI=
2 bytes
Command or Query.
Sets the interval at which statistics are logged. Minimum
resolution is 1 minute, maximum is 99 minutes.
Example:
<1/SSI=90’cr’
>0001/SSI=’cr’’lf’
Default Value:
90
SSI=
SSI?
SSI?
SSI=xx
(Same
format as
command
arguments)
SNMP
System
Location
SSL=
255 bytes,
characters
Command or Query.
SNMP System Location string
Example:
<1/SSL=Upstairs back right
If not configured it returns empty string. <1/SSL=
SSL =
SSL!
SSL?
SSL =x
[1..128]
(See
description
of
arguments)
SNMP
Unit Name
SCN=
16 bytes,
characters
Command or Query.
SNMP System Name string
Example:
<1/SCN=Remote1
If not configured it returns empty string. <1/SCN=
SCN =
SCN!
SCN?
SCN =x
[1..128]
(See
description
of
arguments)
SNMP Trap
Destination
IP Address 1
STA=
15 bytes,
Numerical
Command or Query.
Used to set the IP address of the first SNMP Trap destination
IP Address 1
Where
traps will be sent in the form:
xxx.xxx.xxx.xxx is the IP addresss
Example:
<1/STA=010.006.030.001
When not configured, returns >0001/STA=0.0.0.0
STA =
STA!
STA?
STA=xxx.xx
x.xxx.xxx
(See
description
of