TRP1000-4450 Troposcatter C-Band Outdoor Amplifier
Revision 0
Serial-based Remote Product Management
5–22
MN-TRP1000-OD
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command
or Response
to Query
Description of Arguments
(Note that all arguments are ASCII
numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response
to Query
(Target to
Controller)
Retrieve
Alarm Status
(Continued)
(continued)
PS1-PFAN3 = Module Fan 3 Speed
Example:
<1/RAS?’cr’
>1/RAS=cr’
SYS-INPWR=NA
SYS-FWPWR=NA
SYS-RVPWR=NA
SYS-OTEMP=OK
SYS-INTMP=OK
SYS-RFOVR=OK
RF1-PS24V=OK
RF1-PS13V=OK
RF1-P5V8T=OK
RF1-N5V8T=OK
RF1-ATEMP=OK
RF1-ETEMP=OK
RF1-RFAN1=OK
RF1-RFAN2=OK
RF1-RFAN3=OK
PS1-PS40V=NA
PS1-PS10V=NA
PS1-PS40I=OK
PS1-PS24I=OK
PS1-PS10I=OK
PS1-P5V8T=OK
PS1-PFAN1=OK
PS1-PFAN2=OK
PS1-PFAN3=OK