Commander Connect Owners Manual
108
To set system timers
You can set various timers from the Programming Station to suit your requirements.
•
From the Programming Station, press the PROGRAM Key
•
Press the Scroll Down Key (
) until ‘System programming’ is displayed
•
Select ‘System programming’
•
Enter the System Programming Password
•
Select ‘System’
•
Press the Scroll Down Key (
) until ‘Timers’ is displayed
•
Select ‘Timers’
•
Select the required timer to be changed and enter the duration. (See table below)
•
Confirm the new time.
Press the Hands-free Key to finish programming.
Timers
Range
Default setting
Recall on hold
001 – 1800
90 seconds
Recall on transfer
001 – 300
30 seconds
Divert on no answer
01 – 30
11 seconds
Courtesy delay
01 – 30
30 seconds
Open the door
01 – 30
5 seconds
Door Station ring duration
01 – 30
30 seconds
Call park
001 – 300
180 seconds
Ringback time duration
01 – 30
30 seconds
Auto Attendant Day
01 – 30
1 seconds
(immediate answer)
Auto-Attendant Night
01 – 30
1 seconds
(immediate answer)
Answer machine delay
01 – 30
10 seconds
Voicemail message length
30 - 300
60 seconds
AA dial time
01 - 05
2 seconds
Hunt timer
001 - 300
15 seconds
Notification Delay
060 – 1800
900 seconds
Notification Interval
060 – 900
300
Courtesy service length
001-300
180 seconds
Recall on Hold
This is the time that elapses before a call, which has been placed on hold, rings back the
Station that put the call on hold.
Recall on transfer
This is the time that elapses before a call, which has been transferred and not answered, rings
back the Station that attempted the transfer.
Divert on no answer
This is the time that elapses before a call ringing at a Station, with ’Divert On No Answer’ set,
is diverted.
Courtesy delay
This is the time that elapses before an unanswered incoming call is presented the courtesy
message.
Open the door
This is the time that the Doorstrike relay will remain open following activation.
Door Station ring duration
This is the time that Stations will ring when the Door Station is pressed.