C0240111-04-05-GB
Slave calibration
offset Value
B3: 0.0°C 12.3°C
B4: 0.0°C 12.3°C
Modifies the probe offsets. (Only present if required by the type of machine
configured)
288
289
Slave calibration
offset Value
B5: 0.0°C 12.3°C
B6: 0.0°C 07.3bar
Modifies the probe offsets. (Only present if required by the type of machine
configured)
290
291
Slave calibration
offset Value
B7: 0.0°C 05.3°C
B8: - -
Modifies the probe offsets. (Only present if required by the type of machine
configured)
292
293
Slave calibration
offset Value
B9: 0.0°C 00.0°C
B10: - -
Modifies the probe offsets. (Only present if required by the type of machine
configured)
294
295
Slave calibr. exp1
offset Value
B1: 0.0°C 35.6°C
B2: 0.0°C 40.5°C
Modifies the probe offsets of expansion 1. (Only present if required by the type of
machine configured)
296
297
Slave calibr. exp1
offset Value
B3: 0.0°C 37.2°C
B4: 0.0°C 37.2°C
Modifies the probe offsets of expansion 1. (Only present if required by the type of
machine configured)
298
299
Slave calibr. exp2
offset Value
B1: 0.0bar 04.2bar
B2: 0.0bar 03.9bar
Modifies the probe offsets of expansion 2. (Only present if required by the type of
machine configured)
300
301
Slave calibr. exp2
offset Value
B3: 0.0°C 35.6°C
B4: 0.0°C 40.5°C
Modifies the probe offsets of expansion 2. (Only present if required by the type of
machine configured)
302
303
Slave calibr. exp2
offset Value
B5: 0.0°C 22.3°C
B6: 0.0°C 24.2°C
Modifies the probe offsets of expansion 2. (Only present if required by the type of
machine configured)
304
305
Slave calibr. exp2
offset Value
B7: 0.0°C 22.4°C
B8: - -
Modifies the probe offsets of expansion 2. (Only present if required by the type of
machine configured)
306
307
Slave calibr. exp3
offset Value
B1: 0.0°C 05.3°C
B2: 0.0°C 00.0°C
Modifies the probe offsets of expansion 3. (Only present if required by the type of
machine configured)
308
309
Slave calibr. exp3
offset Value
B3: 0.0°C 00.0°C
B4: 0.0°C 00.0°C
Modifies the probe offsets of expansion 3. (Only present if required by the type of
machine configured)
310
311
Slave calibr. exp5
offset Value
B1: 0.0°C 00.0°C
B2: 0.0°C 00.0°C
Modifies the probe offsets of expansion 5. (Only present if required by the type of
machine configured)
312
313
Slave calibr. exp5
offset Value
B3: 0.0°C 00.0°C
B4: 0.0°C 00.0°C
Modifies the probe offsets of expansion 5. (Only present if required by the type of
machine configured)
314
315
Service
m
p
Access mask to assistance submenu. Press "Up" or "Down" to scroll the other
masks and "Esc" to return to the submenu.
Hour counter
Pump:
Threshold 012x1000
Reset N° 000000
Sets the threshold for programmed maintenance on the evaporator pump.
316
Hour counter
Pump 2:
Threshold 012x1000
Reset N° 000000
Sets the threshold for programmed maintenance on pump 2. (this may be pump
2 of the evaporator or the pump on the secondary circuit in the water/water units
or the recuperator pump, depending on unit configuration)
317
Hour counter
Compressor 1:
Threshold 010x1000
Reset N° 000000
Sets the threshold for programmed maintenance.
318
Hour counter
Compressor 2:
Threshold 010x1000
Reset N° 000000
Sets the threshold for programmed maintenance.
319
Hour counter
Compressor 3:
Threshold 010x1000
Reset N° 000000
Sets the threshold for programmed maintenance.
320
52