802.1X Commands
103
Cisco Sx350 Ph. 2.2.5 Devices - Command Line Interface Reference Guide
3
Default Configuration
The default quiet period is 60 seconds.
Command Mode
Interface (Ethernet) Configuration mode
User Guidelines
During the quiet period, the device does not accept or initiate authentication
requests.
The default value of this command should only be changed to adjust to unusual
circumstances, such as unreliable links or specific behavioral problems with
certain clients and authentication servers.
To provide faster response time to the user, a smaller number than the default
value should be entered.
For 802.1x and MAC-based authentication, the number of failed logins is 1.
For WEB-based authentication, the quite period is applied after a number of failed
attempts. This number is configured by the
For 802.1x-based and MAC-based authentication methods, the quite period is
applied after each failed attempt.
Example
The following example sets the time interval that the device remains in the quiet
state following a failed authentication exchange to 120 seconds.
switchxxxxxx(config)#
interface
gi11
switchxxxxxx(config-if)#
dot1x timeout quiet-period
120
3.21 dot1x timeout reauth-period
To set the number of seconds between re-authentication attempts, use the dot1x
timeout reauth-period command in Interface Configuration mode. To restore the
default configuration, use the no form of this command.
Syntax
dot1x timeout reauth-period
seconds
Summary of Contents for Sx350
Page 1: ...Cisco Sx350 Ph 2 2 5 Devices Command Line Interface Reference Guide CLI GUIDE ...
Page 26: ...25 Cisco Sx350 Ph 2 2 5 Devices Command Line Interface Reference Guide 1 ...
Page 237: ...CDP Commands Cisco Sx350 Ph 2 2 5 Devices Command Line Interface Reference Guide 236 8 ...
Page 975: ...RADIUS Commands Cisco Sx350 Ph 2 2 5 Devices Command Line Interface Reference Guide 974 48 ...